A multi-stage cascade system uses more than one heating and cooling source (H/C Source) to keep your home comfortable. It’s also known as a hybrid heating system. For example, a home might have a main heat pump, a second heat pump, and an electric backup heater. In a Messana system, all of these sources can share one buffer tank.
Messana Controls decide which source runs, and when. The main heat pump does most of the work. The other sources only switch on, one step at a time, when they’re really needed. As a result, you get the best possible efficiency on mild days and reliable comfort on the coldest ones.
Why use a multi-stage cascade system?
A single heat pump is very efficient, but on extremely cold days it may not be enough on its own. A multi-stage cascade system solves this:
- Top efficiency. The main heat pump covers most of the load, so the system runs on the most efficient source most of the time.
- Comfort in extreme weather. Extra sources and a backup heater step in only when the main heat pump can’t keep up.
- Hot water comes first. The system handles domestic hot water (DHW) priority on its own, without any manual steps. By taking priority if the system manages DHW.
How Messana stages your heat sources
- 1st stage switches on first.
- 2nd stage switches on if heating is still needed after a set delay (30 minutes by default).
- Backup switches on after another delay (30 minutes by default), but only if the outdoor temperature is below a set limit. On milder days, the backup stays off.
Multi-stage cascade system staging: 1st stage on, 2nd stage after 30 minutes, backup after another 30 minutes only when it is cold outside. This applies for cooling as well
Several sources sharing a buffer tank
When several H/C Sources share a buffer tank, your installer gives each one a priority order in the Messana App. The source with the lowest number starts first. Then, as demand rises, the buffer tank logic switches on the next source in the order, up to the level of demand.
For example:
| Priority order | Source | When it runs |
|---|---|---|
| 1 | Main heat pump | First, on every call for heat |
| 2 | Second heat pump | When the first one can’t keep up |
| 3 | Electric backup heater | Last, and only when it’s cold enough outside |
What happens when you need hot water?
If your Messana system is connected to your Domestic hot water system. Domestic hot water has priority. DHW request can interrupt the staging cascade if needed to produce appropriate hot water. The system handles this automatically, so you don’t need to do anything.
Want to add a backup source to your system?
Planning a multi-stage cascade system, or adding a source to an existing one? Please talk to your installer or contact us. For help with problems on an existing system, please open a support case.